emailsales@synaccess.comphone+1 619-209-8077
How to Buy
Demo
Company
Press
synaccess-logo
SynLink Technology
Products
Resources
Support
Cart
Contact Us
synaccess-logo
Cart
menu
homeHome
chevron_right
Productschevron_right
MP-4001

0U Single Phase Metered

Customizearrow_downward
Reliable and Cost Effective Power Distribution Solution
MP-4001 is our Basic 0U PDU delivering Single-Phase power to 24x to 36x outlets. These cost-effective PDUs reliably deliver unfiltered power to your equipment while meeting budget demands. Ideal for Datacenters, IT Racks, Engineering Labs, and more!
We're here to help. Call +1 619-209-8077 orSend us an Email
Contact Us for a Quote
Datasheet
Customizearrow_downward
Key Stats
Model Name
MP-4001
Form Factor
0U
Max Input Current
20A
Power Capacity
1.9kVA - 3.8kVA
Inlet Voltage(s)
120V,208V,240V
# Outlets
24,36
Included Features
Input Power Measurements
Input Power Measurements
Current Measurements at Input
Local Current Display
Local Current Display
7-Segment LED Display to display current consumption.
Hot-Swappable Control Module
Hot-Swappable Control Module
PDUs with this feature can hot swap control modules for upgrade or service while maintaining power to the outlets.

Inlet Plug Options

IEC-320 C20
IEC-320 C20

Outlet Receptacle Options

NEMA 5-20R(24)
NEMA 5-20R
NEMA 5-20R Outlet Configuration
C13(20) + C19(4)
IEC 60320 C13
IEC 60320 C13 Outlet Configuration
IEC 60320 C19
IEC 60320 C19 Outlet Configuration
Customized PDU
Inlet(s):undefined (undefined)
Outlet Receptacles:
Voltage:
Power Capacity:
Max Input Current:
Circuit Breaker Protection:undefined Pole Circuit Breakers
Switching:Not Included
Outlet Current Measurements:Not Included
Inlet Measurements:Not Included
Dimensions:
Package Includes:
  • Attached Plug
  • Quick Start Guide Reference Pamphlet

Model Specifications

Input
Plug Types
IEC-320 C20
Input Voltage(s)
120V,208V,240V
Max Input Current
20A
Power Capacity
1.9kVA - 3.8kVA
Phase
1
Output
Outlet Voltages
120V,208V,240V
Outlet Receptacles
NEMA 5-20R(24), C13(20) + C19(4)
Total Number of Outlets
24,36
Overload Protection
None
Physical
Form Factor
0U
Dimensions (hwd)
58.13"-70.00" x 2.20" x 2.20"
Operating Temperature Range
0C to +65C
Relative Humidity
5-95% (non-condensing)
Maximum Operating Elevation
0-10,000 ft / 0 - 3,000 m

Safety Certified yet Cost-Effective Rackmount Metered PDU Solution

Though we carry the most budget-friendly basic PDUs in the market, we do not cut corners. Our PDUs are stamped with the latest UL-62368-1 Certification. In addition, each PDU goes through a series of vibe, heat and shock testing before leaving the factory. HiPot and Ground Bond are done to ensure Electrical safety to the user.







 

 

High Precision Current Readings

Fast and accurate real-time current RMS readings from 0.0A to 20.0A on each circuit (up to one decimal place). Flashing display alerts users of overload conditions.

Unfiltered Power Perfect With UPS Systems

True unfiltered power that is suitable for distributing UPS power to downstream devices. The rugged, all-steel enclosure ensures that power is continually delivered to your devices without interruption.

Optimized for Function While Eliminating Cost

We worked side-by-side our customers for over 20 years and we understand what works and what does not. Our Metered PDUs are designed with budget demands in mind while ensuring safe and reliable performance.



All PDU’s are UL62368-1 Certified to deliver the safest and most reliable performance. In addition, all of our PDUs come with a standard 3-year warranty to give you the best confidence in your investment.

SynLink Series Comparison

Switched Pro+
Remote access. Switched outlets, circuit-level energy monitoring (KWH), and outlet-level power (Amps).
Switched
Remote access. Switched outlets and circuit-level current (Amps).
Monitored
Remote access. Circuit-level energy monitoring (KWH).
Metered
Reliable, Cost-Effective PDU with local current metering

Notable Features

inletpower
Circuit-Level Current Meter
(Accurate to 0.01 A)
(Accurate to 0.01 A)
(Accurate to 0.01 A)
(Accurate to 0.1 A)
ethernet
Networking
SNMP, DCIM, HTTP(s), SMTP, Syslog, Serial, Telnet, SSH, Ping, DHC, NTP, TCP/IP, UDP, DNS, DHCP, CLI
controlunit
Self-Monitoring Network Card
Built-in network watchdog
temp
Sensors and Accessories Support
Temperature and Humidity, USB WiFi
synlinkport
Expansion Ports ***
Daisy chain multiple PDUs
relayhealth
Outlet Switching
Relay Health Monitor uses dedicated voltage sensors for each relay
inletenergy
Circuit and Inlet-Level Energy Monitor
Energy accumulation KWH, Apparent power VA, Active Power W, Power Factor, Line Frequency, Voltage V, Current A
outletload
Outlet-Level Power Meter
Active power W, Voltage RMS V, Current RMS A
ats
Automatic Transfer Switch *
Optional
Optional
Optional
Optional
multiinlet
High Powered Multi Inlet**
Optional **
Optional **
Optional
Optional

Mechanical

lcd
Local Display
Color TFT LCD
Color TFT LCD
Color TFT LCD
7-Segment (1x Per Circuit)
formfactor
Form Factors - 0U, 1U, 2U
ruggedenclosure
Durable Metal Enclosure
hotswap
Hot-swappable Current Meter (Field-Replaceable)
easymount
0U Quick Install with Button Mounts
controlunit
Local and Remote Firmware Upgrade

Security

personalaccesstoken
Personal Access Token Authentication
userpermissions
User Permissions and Roles
ssh
SSH
web
HTTPS
ssl
SSL/TLS
userpermissions
LDAP/Radius ***

Reliability & Safety

warranty
3-Year Standard Warranty
ul
UL/CSA 62368-1 : 2019 Third Edition Compliant
SynLink Switched Pro+
SynLink Switched
SynLink Monitored
Metered
* Only applicable to single-phase PDUs.
** Not available in 1U Form Factors.
*** Planned and coming soon.

Metered

Notable Features

Circuit-Level Current Meter
Automatic Transfer Switch *
Optional
High Powered Multi Inlet**
Optional

Mechanical

Local Display
Form Factors - 0U, 1U, 2U
Durable Metal Enclosure
Hot-swappable Current Meter (Field-Replaceable)
0U Quick Install with Button Mounts

Security

Reliability & Safety

3-Year Standard Warranty
UL/CSA 62368-1 : 2019 Third Edition Compliant

SynLink Monitored

Notable Features

Circuit-Level Current Meter
Networking
SNMP, DCIM, HTTP(s), SMTP, Syslog, Serial, Telnet, SSH, Ping, DHC, NTP, TCP/IP, UDP, DNS, DHCP, CLI
Self-Monitoring Network Card
Built-in network watchdog
Sensors and Accessories Support
Temperature and Humidity, USB WiFi
Expansion Ports ***
Daisy chain multiple PDUs
Circuit and Inlet-Level Energy Monitor
Energy accumulation KWH, Apparent power VA, Active Power W, Power Factor, Line Frequency, Voltage V, Current A
Automatic Transfer Switch *
Optional
High Powered Multi Inlet**
Optional

Mechanical

Local Display
Form Factors - 0U, 1U, 2U
Durable Metal Enclosure
Hot-swappable Current Meter (Field-Replaceable)
0U Quick Install with Button Mounts
Local and Remote Firmware Upgrade

Security

Personal Access Token Authentication
User Permissions and Roles
SSH
HTTPS
SSL/TLS
LDAP/Radius ***

Reliability & Safety

3-Year Standard Warranty
UL/CSA 62368-1 : 2019 Third Edition Compliant

SynLink Switched Pro+

Notable Features

Circuit-Level Current Meter
Networking
SNMP, DCIM, HTTP(s), SMTP, Syslog, Serial, Telnet, SSH, Ping, DHC, NTP, TCP/IP, UDP, DNS, DHCP, CLI
Self-Monitoring Network Card
Built-in network watchdog
Sensors and Accessories Support
Temperature and Humidity, USB WiFi
Expansion Ports ***
Daisy chain multiple PDUs
Outlet Switching
Relay Health Monitor uses dedicated voltage sensors for each relay
Circuit and Inlet-Level Energy Monitor
Energy accumulation KWH, Apparent power VA, Active Power W, Power Factor, Line Frequency, Voltage V, Current A
Outlet-Level Power Meter
Active power W, Voltage RMS V, Current RMS A
Automatic Transfer Switch *
Optional
High Powered Multi Inlet**
Optional **

Mechanical

Local Display
Form Factors - 0U, 1U, 2U
Durable Metal Enclosure
Hot-swappable Current Meter (Field-Replaceable)
0U Quick Install with Button Mounts
Local and Remote Firmware Upgrade

Security

Personal Access Token Authentication
User Permissions and Roles
SSH
HTTPS
SSL/TLS
LDAP/Radius ***

Reliability & Safety

3-Year Standard Warranty
UL/CSA 62368-1 : 2019 Third Edition Compliant

Available Configurations

Filter Byexpand_more
Input Plug
Circuit Breakers
Voltage
Outlets
Inlet Current Metering
2 PDUs
view_listListtoggle_offview_moduleCard
Part Number
Phase
Input Plug
Circuit Breakers
Voltage
Max Amps
Power Capacity
Outlets
Inlet Current Metering
Part Number0
Metered PDUMP-4001EIE-07
Phase1
1
Input Plug2
IEC-320 C20
Circuit Breakers3
None
Voltage4
120V
Max Amps5
20A (16A)
Power Capacity6
1.9kVA
Outlets7
NEMA 5-20R(24)
Inlet Current Metering8
check
9
See Details
Add To Cart
Metered PDUMP-4001EIE-07
1
IEC-320 C20
None
120V
20A (16A)
1.9kVA
NEMA 5-20R(24)
check
See Details
Add To Cart
Part Number0
Metered PDUMP-4001EIE-09
Phase1
1
Input Plug2
IEC-320 C20
Circuit Breakers3
None
Voltage4
120V, 208V, 240V
Max Amps5
20A (16A)
Power Capacity6
1.9kVA, 3.3kVA, 3.8 kVA
Outlets7
C13(20) + C19(4)
Inlet Current Metering8
check
9
See Details
Add To Cart
Metered PDUMP-4001EIE-09
1
IEC-320 C20
None
120V, 208V, 240V
20A (16A)
1.9kVA, 3.3kVA, 3.8 kVA
C13(20) + C19(4)
check
See Details
Add To Cart
synaccess-logo
Resources
Blogs
Press
White Papers
Case Studies
SynLink Brochure (PDF)
SynLink Mining OS Beta
Company
About Us
Contact Us
How To Buy
Privacy Policy
Terms of Agreement
Products
SynLink Technology
Product Lines
Product Finder
SynLink Live Demo
Accessories
SynLink Desktop App
Support
Support Overview
Knowledge Base
Documents & Downloads
Returns & Accepted Payment Options
Warranty
Firmware Changelog
Sign up for updates
2629 Ariane Drive, San Diego, CA 92117
© 2024 Synaccess LLC. All Rights Reserved.